We offer free shipping on all orders

{"id":9137761353965,"title":"AC Service Tech LLC HVAC Quick Reference Cards for Refrigerant Charging and Troubleshooting","handle":"ac-service-tech-llc-hvac-quick-reference-cards-for-refrigerant-charging-and-troubleshooting","description":"\u003ch3\u003eAC Service Tech LLC HVAC Quick Reference Cards for Refrigerant Charging and Troubleshooting\u003c\/h3\u003e\r\n\u003cp id=\"b\"\u003eThese three HVAC quick reference polystyrene cards are double sided and\r\ndesigned to be used with Air Conditioners and Heat Pumps to measure the\r\nrefrigerant level in a unit, charge refrigerant, troubleshoot refrigerant\r\nbased problems, and measure heat transfer to determine if there is a problem.\r\nFind the Target Subcooling to measure the refrigerant level of systems with a\r\nTXV metering device Use Subcooling to determine if a system is undercharged,\r\ncorrectly charged, or overcharged Find the Target Superheat to measure the\r\nrefrigerant level of systems with a fixed orifice metering device Use Total\r\nSuperheat to determine if a system is undercharged, correctly charged, or\r\novercharged Use Delta T to determine if the system is exchanging heat properly\r\nUse the P\/T Chart to find the Saturated Temp of 5 common refrigerants Use the\r\nGuide to determine how to find the Bubble and Dew Saturated Temps of Blend\r\nRefrigerants Use the Refrigerant Weight Chart to calculate the amount of\r\nrefrigerant needed per foot of tubing Use the Guide to weigh in the full or\r\npartial refrigerant charge into an empty vacuumed unit\u003c\/p\u003e \r\n\r\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\r\n \u003cul class=\"a\"\u003e\r\n \u003cli\u003eFlexible\u003c\/li\u003e\r\n \u003cli\u003eWeather and UV Resistant\u003c\/li\u003e\r\n \u003cli\u003ePolystyrene Card Material Tested 0F-130F\u003c\/li\u003e\r\n \u003cli\u003eThree Cards Double Sided per Pack\u003c\/li\u003e\r\n \u003cli\u003eHVAC Technician Resource\u003c\/li\u003e\r\n \u003c\/ul\u003e","published_at":"2025-10-13T21:07:05+11:00","created_at":"2025-10-13T21:07:02+11:00","vendor":"AC Service Tech LLC","type":"Diagnostic Equipment","tags":["AUTO_bestsellers_Oct2025"],"price":16000,"price_min":16000,"price_max":16000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":48865655193837,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"B082895BBX","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AC Service Tech LLC HVAC Quick Reference Cards for Refrigerant Charging and Troubleshooting","public_title":null,"options":["Default Title"],"price":16000,"weight":141,"compare_at_price":null,"inventory_management":"shopify","barcode":"860003018705","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/leoforward.com\/cdn\/shop\/files\/B082895BBX.jpg?v=1775783632","\/\/leoforward.com\/cdn\/shop\/files\/41c3JcbImsL.jpg?v=1760350024","\/\/leoforward.com\/cdn\/shop\/files\/5179TJuwkrL.jpg?v=1760350024","\/\/leoforward.com\/cdn\/shop\/files\/511D1zhwP0L.jpg?v=1760350024"],"featured_image":"\/\/leoforward.com\/cdn\/shop\/files\/B082895BBX.jpg?v=1775783632","options":["Title"],"media":[{"alt":null,"id":36890018644205,"position":1,"preview_image":{"aspect_ratio":1.066,"height":362,"width":386,"src":"\/\/leoforward.com\/cdn\/shop\/files\/B082895BBX.jpg?v=1775783632"},"aspect_ratio":1.066,"height":362,"media_type":"image","src":"\/\/leoforward.com\/cdn\/shop\/files\/B082895BBX.jpg?v=1775783632","width":386},{"alt":null,"id":36890018676973,"position":2,"preview_image":{"aspect_ratio":1.066,"height":361,"width":385,"src":"\/\/leoforward.com\/cdn\/shop\/files\/41c3JcbImsL.jpg?v=1760350024"},"aspect_ratio":1.066,"height":361,"media_type":"image","src":"\/\/leoforward.com\/cdn\/shop\/files\/41c3JcbImsL.jpg?v=1760350024","width":385},{"alt":null,"id":36890018709741,"position":3,"preview_image":{"aspect_ratio":1.299,"height":301,"width":391,"src":"\/\/leoforward.com\/cdn\/shop\/files\/5179TJuwkrL.jpg?v=1760350024"},"aspect_ratio":1.299,"height":301,"media_type":"image","src":"\/\/leoforward.com\/cdn\/shop\/files\/5179TJuwkrL.jpg?v=1760350024","width":391},{"alt":null,"id":36890018742509,"position":4,"preview_image":{"aspect_ratio":1.297,"height":303,"width":393,"src":"\/\/leoforward.com\/cdn\/shop\/files\/511D1zhwP0L.jpg?v=1760350024"},"aspect_ratio":1.297,"height":303,"media_type":"image","src":"\/\/leoforward.com\/cdn\/shop\/files\/511D1zhwP0L.jpg?v=1760350024","width":393}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eAC Service Tech LLC HVAC Quick Reference Cards for Refrigerant Charging and Troubleshooting\u003c\/h3\u003e\r\n\u003cp id=\"b\"\u003eThese three HVAC quick reference polystyrene cards are double sided and\r\ndesigned to be used with Air Conditioners and Heat Pumps to measure the\r\nrefrigerant level in a unit, charge refrigerant, troubleshoot refrigerant\r\nbased problems, and measure heat transfer to determine if there is a problem.\r\nFind the Target Subcooling to measure the refrigerant level of systems with a\r\nTXV metering device Use Subcooling to determine if a system is undercharged,\r\ncorrectly charged, or overcharged Find the Target Superheat to measure the\r\nrefrigerant level of systems with a fixed orifice metering device Use Total\r\nSuperheat to determine if a system is undercharged, correctly charged, or\r\novercharged Use Delta T to determine if the system is exchanging heat properly\r\nUse the P\/T Chart to find the Saturated Temp of 5 common refrigerants Use the\r\nGuide to determine how to find the Bubble and Dew Saturated Temps of Blend\r\nRefrigerants Use the Refrigerant Weight Chart to calculate the amount of\r\nrefrigerant needed per foot of tubing Use the Guide to weigh in the full or\r\npartial refrigerant charge into an empty vacuumed unit\u003c\/p\u003e \r\n\r\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\r\n \u003cul class=\"a\"\u003e\r\n \u003cli\u003eFlexible\u003c\/li\u003e\r\n \u003cli\u003eWeather and UV Resistant\u003c\/li\u003e\r\n \u003cli\u003ePolystyrene Card Material Tested 0F-130F\u003c\/li\u003e\r\n \u003cli\u003eThree Cards Double Sided per Pack\u003c\/li\u003e\r\n \u003cli\u003eHVAC Technician Resource\u003c\/li\u003e\r\n \u003c\/ul\u003e"}

AC Service Tech LLC HVAC Quick Reference Cards for Refrigerant Charging and Troubleshooting

In Stock. Leaves warehouse within 2 - 3 business days

$160.00 AUD
Maximum quantity available reached.
Free Shipping Australia Wide
100% Safe & Secure Checkout
100 Days Return Policy *
1 Year Warranty *

AC Service Tech LLC HVAC Quick Reference Cards for Refrigerant Charging and Troubleshooting

These three HVAC quick reference polystyrene cards are double sided and designed to be used with Air Conditioners and Heat Pumps to measure the refrigerant level in a unit, charge refrigerant, troubleshoot refrigerant based problems, and measure heat transfer to determine if there is a problem. Find the Target Subcooling to measure the refrigerant level of systems with a TXV metering device Use Subcooling to determine if a system is undercharged, correctly charged, or overcharged Find the Target Superheat to measure the refrigerant level of systems with a fixed orifice metering device Use Total Superheat to determine if a system is undercharged, correctly charged, or overcharged Use Delta T to determine if the system is exchanging heat properly Use the P/T Chart to find the Saturated Temp of 5 common refrigerants Use the Guide to determine how to find the Bubble and Dew Saturated Temps of Blend Refrigerants Use the Refrigerant Weight Chart to calculate the amount of refrigerant needed per foot of tubing Use the Guide to weigh in the full or partial refrigerant charge into an empty vacuumed unit

Product Features

  • Flexible
  • Weather and UV Resistant
  • Polystyrene Card Material Tested 0F-130F
  • Three Cards Double Sided per Pack
  • HVAC Technician Resource