{"id":8138975969517,"title":"Current Sensing Relay AC Current Sensing Switch 0-200A Normally Closed Amp Sensor Monitoring Relay (M3086) M3086","handle":"current-sensing-relay-ac-current-sensing-switch-0-200a-normally-closed-amp-sensor-monitoring-relay-m3086-m3086","description":"\u003ch3\u003eCurrent Sensing Relay AC Current Sensing Switch 0-200A Normally Closed Amp Sensor Monitoring Relay (M3086)\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eProduct parameters:Monitoring Current: 0.2-200A ACContact capacity: 0.3A at\n240V AC\/DCcontactor, relayPerforation Line Diameter: 10mmDimensions:\n70x27x50mm.Maximum overload: 100%of the power switch [supply line switching\nsignalOperating temperature: -20 - 55 °C.Hysteresis: less than 1%package\nlist:Current Sensing Switch x 1user's manual x 1\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eNormally closed current sensing switch: when the perforation line current exceeds the set value, the green light is on and the output signal is open. The AC and DC load indirectly, when the current is less than the set value, the red light is off and the switch is off is closed\u003c\/li\u003e\n \u003cli\u003eMutual inductive current monitoring, safety isolation of input and output, self-current monitoring\u003c\/li\u003e\n \u003cli\u003eThe range of the monitored current is up to 200 A, the monitoring threshold is adjustable\u003c\/li\u003e\n \u003cli\u003eHysteresis is less than 1%. It can be used in devices to monitor strong magnetic environment.\u003c\/li\u003e\n \u003cli\u003eNon-contact electronic switch with fast response and unlimited number of on and off operations\u003c\/li\u003e\n \u003c\/ul\u003e","published_at":"2023-03-06T17:11:22+11:00","created_at":"2023-03-06T17:11:28+11:00","vendor":"Lelukee","type":"","tags":["industrial_Dec2022"],"price":15200,"price_min":15200,"price_max":15200,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":44003136110829,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"B09VDNJD9G","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Current Sensing Relay AC Current Sensing Switch 0-200A Normally Closed Amp Sensor Monitoring Relay (M3086) M3086","public_title":null,"options":["Default Title"],"price":15200,"weight":120,"compare_at_price":null,"inventory_management":null,"barcode":"Lelukee22020801","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/leoforward.com\/cdn\/shop\/products\/515wSElaprL.jpg?v=1678083088","\/\/leoforward.com\/cdn\/shop\/products\/51qmQU7u6yL.jpg?v=1678083088","\/\/leoforward.com\/cdn\/shop\/products\/51I71XOCM-L.jpg?v=1678083088","\/\/leoforward.com\/cdn\/shop\/products\/616_u86MWbL.jpg?v=1678083088","\/\/leoforward.com\/cdn\/shop\/products\/61QOZ43nRyL.jpg?v=1678083088"],"featured_image":"\/\/leoforward.com\/cdn\/shop\/products\/515wSElaprL.jpg?v=1678083088","options":["Title"],"media":[{"alt":" [AUSTRALIA] - Current Sensing Relay AC Current Sensing Switch 0-200A Normally Closed Amp Sensor Monitoring Relay (M3086) M3086","id":31184067789037,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1001,"width":1001,"src":"\/\/leoforward.com\/cdn\/shop\/products\/515wSElaprL.jpg?v=1678083088"},"aspect_ratio":1.0,"height":1001,"media_type":"image","src":"\/\/leoforward.com\/cdn\/shop\/products\/515wSElaprL.jpg?v=1678083088","width":1001},{"alt":" [AUSTRALIA] - Current Sensing Relay AC Current Sensing Switch 0-200A Normally Closed Amp Sensor Monitoring Relay (M3086) M3086","id":31184067821805,"position":2,"preview_image":{"aspect_ratio":1.138,"height":1001,"width":1139,"src":"\/\/leoforward.com\/cdn\/shop\/products\/51qmQU7u6yL.jpg?v=1678083088"},"aspect_ratio":1.138,"height":1001,"media_type":"image","src":"\/\/leoforward.com\/cdn\/shop\/products\/51qmQU7u6yL.jpg?v=1678083088","width":1139},{"alt":" [AUSTRALIA] - Current Sensing Relay AC Current Sensing Switch 0-200A Normally Closed Amp Sensor Monitoring Relay (M3086) M3086","id":31184067854573,"position":3,"preview_image":{"aspect_ratio":1.444,"height":1001,"width":1445,"src":"\/\/leoforward.com\/cdn\/shop\/products\/51I71XOCM-L.jpg?v=1678083088"},"aspect_ratio":1.444,"height":1001,"media_type":"image","src":"\/\/leoforward.com\/cdn\/shop\/products\/51I71XOCM-L.jpg?v=1678083088","width":1445},{"alt":" [AUSTRALIA] - Current Sensing Relay AC Current Sensing Switch 0-200A Normally Closed Amp Sensor Monitoring Relay (M3086) M3086","id":31184067887341,"position":4,"preview_image":{"aspect_ratio":1.472,"height":678,"width":998,"src":"\/\/leoforward.com\/cdn\/shop\/products\/616_u86MWbL.jpg?v=1678083088"},"aspect_ratio":1.472,"height":678,"media_type":"image","src":"\/\/leoforward.com\/cdn\/shop\/products\/616_u86MWbL.jpg?v=1678083088","width":998},{"alt":" [AUSTRALIA] - Current Sensing Relay AC Current Sensing Switch 0-200A Normally Closed Amp Sensor Monitoring Relay (M3086) M3086","id":31184067920109,"position":5,"preview_image":{"aspect_ratio":1.798,"height":1001,"width":1800,"src":"\/\/leoforward.com\/cdn\/shop\/products\/61QOZ43nRyL.jpg?v=1678083088"},"aspect_ratio":1.798,"height":1001,"media_type":"image","src":"\/\/leoforward.com\/cdn\/shop\/products\/61QOZ43nRyL.jpg?v=1678083088","width":1800}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eCurrent Sensing Relay AC Current Sensing Switch 0-200A Normally Closed Amp Sensor Monitoring Relay (M3086)\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eProduct parameters:Monitoring Current: 0.2-200A ACContact capacity: 0.3A at\n240V AC\/DCcontactor, relayPerforation Line Diameter: 10mmDimensions:\n70x27x50mm.Maximum overload: 100%of the power switch [supply line switching\nsignalOperating temperature: -20 - 55 °C.Hysteresis: less than 1%package\nlist:Current Sensing Switch x 1user's manual x 1\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eNormally closed current sensing switch: when the perforation line current exceeds the set value, the green light is on and the output signal is open. The AC and DC load indirectly, when the current is less than the set value, the red light is off and the switch is off is closed\u003c\/li\u003e\n \u003cli\u003eMutual inductive current monitoring, safety isolation of input and output, self-current monitoring\u003c\/li\u003e\n \u003cli\u003eThe range of the monitored current is up to 200 A, the monitoring threshold is adjustable\u003c\/li\u003e\n \u003cli\u003eHysteresis is less than 1%. It can be used in devices to monitor strong magnetic environment.\u003c\/li\u003e\n \u003cli\u003eNon-contact electronic switch with fast response and unlimited number of on and off operations\u003c\/li\u003e\n \u003c\/ul\u003e"}

Current Sensing Relay AC Current Sensing Switch 0-200A Normally Closed Amp Sensor Monitoring Relay (M3086) M3086

In Stock. Leaves warehouse within 2 - 3 business days

$152.00 AUD
Maximum quantity available reached.
Free Shipping Australia Wide
100% Safe & Secure Checkout
100 Days Return Policy *
1 Year Warranty *

Current Sensing Relay AC Current Sensing Switch 0-200A Normally Closed Amp Sensor Monitoring Relay (M3086)

Product parameters:Monitoring Current: 0.2-200A ACContact capacity: 0.3A at 240V AC/DCcontactor, relayPerforation Line Diameter: 10mmDimensions: 70x27x50mm.Maximum overload: 100%of the power switch [supply line switching signalOperating temperature: -20 - 55 °C.Hysteresis: less than 1%package list:Current Sensing Switch x 1user's manual x 1

Product Features

  • Normally closed current sensing switch: when the perforation line current exceeds the set value, the green light is on and the output signal is open. The AC and DC load indirectly, when the current is less than the set value, the red light is off and the switch is off is closed
  • Mutual inductive current monitoring, safety isolation of input and output, self-current monitoring
  • The range of the monitored current is up to 200 A, the monitoring threshold is adjustable
  • Hysteresis is less than 1%. It can be used in devices to monitor strong magnetic environment.