Enter FORWARD5 at Checkout for 5% OFF & Free Shipping in Australia

{"id":6856449556635,"title":"Digital Turbine Flow Meter, 1.5″ Diesel Fuel Flow Meter with NPT Counter Gas Oil Fuel Flowmeter for Measure Diesel, Kerosene, Gasoline 1.5 inch","handle":"digital-turbine-flow-meter-1-5-diesel-fuel-flow-meter-with-npt-counter-gas-oil-fuel-flowmeter-for-measure-diesel-kerosene-gasoline-1-5-inch","description":"\u003ch3\u003eDigital Turbine Flow Meter, 1.5″ Diesel Fuel Flow Meter with NPT Counter Gas Oil Fuel Flowmeter for Measure Diesel, Kerosene, Gasoline\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eSize:1.5 inch Specification: Product Material: Stainless steel, aluminum alloy\nNominal diameter: 1.5 inch Minimum flow: 40L\/min Maximum flow: 280L\/min Flow\nUnit: Littre Maximum working pressure: 20KG Single counting range: 9999.9\nWeight: 0.6KG Package Include:1 Digital Turbine Flowmeter1 User\nManualNote:1. When it appears - normal flow rate but the meter does not count,\nwhen the DISPLAY button is pressed, the meter is turned on. In this case, the\npossible cause is: (1). the impeller is stuck or damaged;(2). the sealant\nmaterial is wrapped around the impeller; Solution: Remove the meter and ensure\nthat the impeller rotates freely.2. When it occurs - the flow rate is reduced\nand the meter does not count when the DISPLAY button is pressed, the meter is\nturned on. In this case, the reasons may be caused by: (1). The meter is\npartially blocked by the dried liquid; (2). Below the minimum flow rate.\nSolution: remove the instrument to ensure that the impeller rotates freely;\nIncrease the flow rate.3. When the meter is not working properly, it may be\ndue to a board failure or a button failure. Solution: replace the circuit\nboard.\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eModular Design: The turbine flow meter have modular design, it makes suitable for use with output modules, sensors and remote transmitters.\u003c\/li\u003e\n \u003cli\u003eDigital LCD Display: High-definition displays show both instantaneous and cumulative flow with NPT counter.\u003c\/li\u003e\n \u003cli\u003eAccuracy: Intuitive clear reading, high reliability, measuring accuracy is 1%.\u003c\/li\u003e\n \u003cli\u003eEasy to Use: The turbine flow meter easy to replace and maintain internal components. Suitable for use with output modules, sensors and remote transmitters.\u003c\/li\u003e\n \u003cli\u003eWidely Use: The pump flow meter can be widely used to measure water,diesel, kerfsene, gasoline, etc.\u003c\/li\u003e\n \u003c\/ul\u003e\n\n\n\n\n","published_at":"2021-06-24T13:19:32+10:00","created_at":"2021-06-24T13:19:32+10:00","vendor":"JUXATECH","type":"Flowmeters","tags":["deletenow","leo109"],"price":26200,"price_min":26200,"price_max":26200,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":40313989464219,"title":"1.5 inch","option1":"1.5 inch","option2":null,"option3":null,"sku":"B08FCG7SL5","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Digital Turbine Flow Meter, 1.5″ Diesel Fuel Flow Meter with NPT Counter Gas Oil Fuel Flowmeter for Measure Diesel, Kerosene, Gasoline 1.5 inch - 1.5 inch","public_title":"1.5 inch","options":["1.5 inch"],"price":26200,"weight":640,"compare_at_price":null,"inventory_management":null,"barcode":"194982276789","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/leoforward.com\/cdn\/shop\/products\/B08FCG7SL5.jpg?v=1651266684","\/\/leoforward.com\/cdn\/shop\/products\/71oX4u2NOoL.jpg?v=1624549766","\/\/leoforward.com\/cdn\/shop\/products\/81tgcbbPqIL.jpg?v=1624549766","\/\/leoforward.com\/cdn\/shop\/products\/71P7JV035yL.jpg?v=1624549766","\/\/leoforward.com\/cdn\/shop\/products\/71TkhjbzSIL.jpg?v=1624549766","\/\/leoforward.com\/cdn\/shop\/products\/81ZluwgYvaL.jpg?v=1624549766"],"featured_image":"\/\/leoforward.com\/cdn\/shop\/products\/B08FCG7SL5.jpg?v=1651266684","options":["Size"],"media":[{"alt":"Digital Turbine Flow Meter, 1.5″ Diesel Fuel Flow Meter with NPT Counter Gas Oil Fuel Flowmeter for Measure Diesel, Kerosene, Gasoline 1.5 inch - LeoForward Australia","id":29656796823789,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1600,"width":1600,"src":"\/\/leoforward.com\/cdn\/shop\/products\/B08FCG7SL5.jpg?v=1651266684"},"aspect_ratio":1.0,"height":1600,"media_type":"image","src":"\/\/leoforward.com\/cdn\/shop\/products\/B08FCG7SL5.jpg?v=1651266684","width":1600},{"alt":"Digital Turbine Flow Meter, 1.5″ Diesel Fuel Flow Meter with NPT Counter Gas Oil Fuel Flowmeter for Measure Diesel, Kerosene, Gasoline 1.5 inch - LeoForward Australia","id":23599053406363,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1600,"width":1600,"src":"\/\/leoforward.com\/cdn\/shop\/products\/71oX4u2NOoL.jpg?v=1624549766"},"aspect_ratio":1.0,"height":1600,"media_type":"image","src":"\/\/leoforward.com\/cdn\/shop\/products\/71oX4u2NOoL.jpg?v=1624549766","width":1600},{"alt":"Digital Turbine Flow Meter, 1.5″ Diesel Fuel Flow Meter with NPT Counter Gas Oil Fuel Flowmeter for Measure Diesel, Kerosene, Gasoline 1.5 inch - LeoForward Australia","id":23599053439131,"position":3,"preview_image":{"aspect_ratio":1.0,"height":1600,"width":1600,"src":"\/\/leoforward.com\/cdn\/shop\/products\/81tgcbbPqIL.jpg?v=1624549766"},"aspect_ratio":1.0,"height":1600,"media_type":"image","src":"\/\/leoforward.com\/cdn\/shop\/products\/81tgcbbPqIL.jpg?v=1624549766","width":1600},{"alt":"Digital Turbine Flow Meter, 1.5″ Diesel Fuel Flow Meter with NPT Counter Gas Oil Fuel Flowmeter for Measure Diesel, Kerosene, Gasoline 1.5 inch - LeoForward Australia","id":23599053471899,"position":4,"preview_image":{"aspect_ratio":1.0,"height":1600,"width":1600,"src":"\/\/leoforward.com\/cdn\/shop\/products\/71P7JV035yL.jpg?v=1624549766"},"aspect_ratio":1.0,"height":1600,"media_type":"image","src":"\/\/leoforward.com\/cdn\/shop\/products\/71P7JV035yL.jpg?v=1624549766","width":1600},{"alt":"Digital Turbine Flow Meter, 1.5″ Diesel Fuel Flow Meter with NPT Counter Gas Oil Fuel Flowmeter for Measure Diesel, Kerosene, Gasoline 1.5 inch - LeoForward Australia","id":23599053504667,"position":5,"preview_image":{"aspect_ratio":1.0,"height":1600,"width":1600,"src":"\/\/leoforward.com\/cdn\/shop\/products\/71TkhjbzSIL.jpg?v=1624549766"},"aspect_ratio":1.0,"height":1600,"media_type":"image","src":"\/\/leoforward.com\/cdn\/shop\/products\/71TkhjbzSIL.jpg?v=1624549766","width":1600},{"alt":"Digital Turbine Flow Meter, 1.5″ Diesel Fuel Flow Meter with NPT Counter Gas Oil Fuel Flowmeter for Measure Diesel, Kerosene, Gasoline 1.5 inch - LeoForward Australia","id":23599053537435,"position":6,"preview_image":{"aspect_ratio":1.0,"height":1600,"width":1600,"src":"\/\/leoforward.com\/cdn\/shop\/products\/81ZluwgYvaL.jpg?v=1624549766"},"aspect_ratio":1.0,"height":1600,"media_type":"image","src":"\/\/leoforward.com\/cdn\/shop\/products\/81ZluwgYvaL.jpg?v=1624549766","width":1600}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eDigital Turbine Flow Meter, 1.5″ Diesel Fuel Flow Meter with NPT Counter Gas Oil Fuel Flowmeter for Measure Diesel, Kerosene, Gasoline\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eSize:1.5 inch Specification: Product Material: Stainless steel, aluminum alloy\nNominal diameter: 1.5 inch Minimum flow: 40L\/min Maximum flow: 280L\/min Flow\nUnit: Littre Maximum working pressure: 20KG Single counting range: 9999.9\nWeight: 0.6KG Package Include:1 Digital Turbine Flowmeter1 User\nManualNote:1. When it appears - normal flow rate but the meter does not count,\nwhen the DISPLAY button is pressed, the meter is turned on. In this case, the\npossible cause is: (1). the impeller is stuck or damaged;(2). the sealant\nmaterial is wrapped around the impeller; Solution: Remove the meter and ensure\nthat the impeller rotates freely.2. When it occurs - the flow rate is reduced\nand the meter does not count when the DISPLAY button is pressed, the meter is\nturned on. In this case, the reasons may be caused by: (1). The meter is\npartially blocked by the dried liquid; (2). Below the minimum flow rate.\nSolution: remove the instrument to ensure that the impeller rotates freely;\nIncrease the flow rate.3. When the meter is not working properly, it may be\ndue to a board failure or a button failure. Solution: replace the circuit\nboard.\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eModular Design: The turbine flow meter have modular design, it makes suitable for use with output modules, sensors and remote transmitters.\u003c\/li\u003e\n \u003cli\u003eDigital LCD Display: High-definition displays show both instantaneous and cumulative flow with NPT counter.\u003c\/li\u003e\n \u003cli\u003eAccuracy: Intuitive clear reading, high reliability, measuring accuracy is 1%.\u003c\/li\u003e\n \u003cli\u003eEasy to Use: The turbine flow meter easy to replace and maintain internal components. Suitable for use with output modules, sensors and remote transmitters.\u003c\/li\u003e\n \u003cli\u003eWidely Use: The pump flow meter can be widely used to measure water,diesel, kerfsene, gasoline, etc.\u003c\/li\u003e\n \u003c\/ul\u003e\n\n\n\n\n"}

Digital Turbine Flow Meter, 1.5″ Diesel Fuel Flow Meter with NPT Counter Gas Oil Fuel Flowmeter for Measure Diesel, Kerosene, Gasoline 1.5 inch

In Stock. Leaves warehouse within 2 - 3 business days

$262.00 AUD
Maximum quantity available reached.
Free Shipping Australia Wide
100% Safe & Secure Checkout
100 Days Return Policy *
1 Year Warranty *

Digital Turbine Flow Meter, 1.5″ Diesel Fuel Flow Meter with NPT Counter Gas Oil Fuel Flowmeter for Measure Diesel, Kerosene, Gasoline

Size:1.5 inch Specification: Product Material: Stainless steel, aluminum alloy Nominal diameter: 1.5 inch Minimum flow: 40L/min Maximum flow: 280L/min Flow Unit: Littre Maximum working pressure: 20KG Single counting range: 9999.9 Weight: 0.6KG Package Include:1 Digital Turbine Flowmeter1 User ManualNote:1. When it appears - normal flow rate but the meter does not count, when the DISPLAY button is pressed, the meter is turned on. In this case, the possible cause is: (1). the impeller is stuck or damaged;(2). the sealant material is wrapped around the impeller; Solution: Remove the meter and ensure that the impeller rotates freely.2. When it occurs - the flow rate is reduced and the meter does not count when the DISPLAY button is pressed, the meter is turned on. In this case, the reasons may be caused by: (1). The meter is partially blocked by the dried liquid; (2). Below the minimum flow rate. Solution: remove the instrument to ensure that the impeller rotates freely; Increase the flow rate.3. When the meter is not working properly, it may be due to a board failure or a button failure. Solution: replace the circuit board.

Product Features

  • Modular Design: The turbine flow meter have modular design, it makes suitable for use with output modules, sensors and remote transmitters.
  • Digital LCD Display: High-definition displays show both instantaneous and cumulative flow with NPT counter.
  • Accuracy: Intuitive clear reading, high reliability, measuring accuracy is 1%.
  • Easy to Use: The turbine flow meter easy to replace and maintain internal components. Suitable for use with output modules, sensors and remote transmitters.
  • Widely Use: The pump flow meter can be widely used to measure water,diesel, kerfsene, gasoline, etc.

Related Products