Enter FORWARD5 at Checkout for 5% OFF & Free Shipping in Australia

{"id":7059908755611,"title":"Current Sensing Switch, Normally Open Current Sensing Relay Adjustable AC 0.2A -30A (SZC23-NO-AL-CH Model)","handle":"current-sensing-switch-normally-open-current-sensing-relay-adjustable-ac-0-2a-30a-szc23-no-al-ch-model","description":"\u003ch3\u003eCurrent Sensing Switch, Normally Open Current Sensing Relay Adjustable AC 0.2A -30A (SZC23-NO-AL-CH Model)\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eFeatures: Self-powered, no external power supply required.\nAction current 0.2-30A AC, adjustable with a potentiometer. LED indicator can\nconveniently and intuitively indicate the working status of the switch. High-\npower MOS tube contactless electronic switch. No limit on the number of\nopening and closing, and the reaction speed reaches the ms level. Straight-\nthrough structure design, isolation withstand voltage up to 2000V. Hysteresis\nis less than 1% and can be used under strong magnetic conditions. The outer\ncasing is made of self-extinguishing material ABS. Specification: Model:\nSZC23-NO-AL-CHPower supply: Not requiredRated load: ≤ 0.5A@240V AC\/DCInput\ncurrent: 0.2-30A ACSwitch on minimum: 0.5±0.2AMaximum overload: 100%Leakage\ncurrent: ≤0.1AAccuracy: 1%Hysteresis: ≤1%Response time: ≤200ms Repeatability:\n100%Working temperature: -20~60℃Waterproof: IP30Dimensions: 652547mm \/\n2.560.981.85inHole diameter: 10mm \/ 0.4inPackage weight: Approx. 56g\/2.0oz\nPackage list: 1 Current Sensing Switch Read more SZC23-NO-AL-CH For example:\nSZC23-NO-AL-CH The meaning is: this device is a current induction switch, the\nmaximum load of the switch is 0.5A@240V AC\/DC; the default is normally open;\nthe switching action current is adjustable; the device is a round fixed port.\n1: Type: SZC is a current induction switch; 2: Model series: The maximum\ncapacity of 23 series switches is 0.5A@240V AC\/DC; 3: NO stands for normally\nopen, that is, when the through-core current is less than the set value, the\nswitch is opened, and when the current is greater than the set value, the\nswitch is closed; 4: Whether the operating current of the switch can be\nadjusted: AL: stands for adjustable, that is, the user can adjust the\noperating current of the switch by himself; 5: The shape of the fixed port of\nthe device: CH stands for the round fixed port, that is, the wire must pass\nthrough the hole. Working Principle: Based on electromagnetic induction, when\nthe current in the circuit changes, an induced current is generated.This\nseries of AC current induction switch uses the inductance coil to induce the\namplitude of the AC current to determine whether it exceeds the preset current\naction value to change the output state of a solid state switch, similar to\nthe function of a mechanical switch. Read more Precautions: Before making\nelectrical connections, disconnect all power supplies in the circuit to avoid\nelectric shock accidents.The meaning of different indicators: For NO normally\nopen type, the green light indicates that the switch is off, current flows\nthrough the switch, but the starting value is not reached, and the contact is\noff; The red light indicates that the switch is closed, the current reaches\nthe starting value, and the contact is closed, the switch is in working\ncondition. Read more SZC23 series AC current sensing switch is designed and\nmanufactured to solve the AC current monitoring. It uses the principle of\nmutual inductance to sense the AC straight-through current, isolate the AC\ncurrent, and output a normally open or normally closed switching signal to\ndirectly control various automation industrial equipment, such as flash,\nbuzzer, relay, single-chip or other power load equipment. Compared with\ntraditional mutual inductors, thermal protectors and other devices, using this\ndevice can not only get more accurate and more timely control, but can also\ngreatly simplify the design and reduce costs.Suitable for AC current\nmeasurement and monitoring, AC motor overload protection, electronic switch of\nautomatic control system and so on. Read more Instructions: Typical Wiring\nDiagram Directly control AC and DC loadsIndirectly control AC and DC loads in\ncombination with contactors Cooperate with PLC to control AC motor Read more\nInstallation Instructions: Disconnect all power supplies in the circuit, and\nfix the AC current sensor switch in a proper position through the mounting\nhole of the base. If you use screws to install, make sure to tighten each\nscrew.Connect the core current loop, first disconnect the tested circuit, let\nthe tested circuit pass through the induction hole of the current switch, and\nreconnect the circuit; Connect the load circuit, note that the maximum AC load\nof this series of current switches cannot exceed 0.5A@240V AC\/DC.After\nchecking that the installation connection is correct, turn on the power switch\nand set the upper and lower limits of the induction switch current according\nto the user's needs: NO normally open type If the red light is on at this\ntime, adjust the potentiometer to the H direction until the green light is on\nand stop, then adjust it to the L direction, and then stop when the red light\nis on. If the green light is on at this time, turn the adjustable\npotentiometer to the L direction until the red light just lights up and stop.\nThe alternating point of the red and green lights is the current value of the\ncurrent through the heart. Common Problems and Solutions: After the\npenetration current reaches the set value, the load circuit is not\nautomatically connected: Solution: Check whether the wiring of the output\nsignal is loose and whether the load circuit wiring is loose. If an AC\ncontactor is used, check whether the wiring of the AC contactor is loose and\nwhether the AC contactor is damaged.After the AC feedthrough current is\napplied, the two LED indicators are off: Solution: Check whether the input AC\ncurrent is normal and whether the wiring is loose.After the AC feedthrough\ncurrent is applied, both LED indicators are on: Solution: The input AC\nfeedthrough current is too large, pay attention to the feedthrough current not\ntoo large, if it exceeds the allowable range of the current sensor switch, the\nswitch will be damaged.\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eSelf-powered, no external power supply required.\u003c\/li\u003e\n \u003cli\u003eAction current 0.2-30A AC, adjustable with a potentiometer.\u003c\/li\u003e\n \u003cli\u003eLED indicator can conveniently and intuitively indicate the working status of the switch.\u003c\/li\u003e\n \u003cli\u003eHigh-power MOS tube contactless electronic switch.\u003c\/li\u003e\n \u003cli\u003eThe switch has no limit on the number of opening and closing, and the reaction speed reaches the ms level.\u003c\/li\u003e\n \u003c\/ul\u003e\n\n\n\n\n","published_at":"2021-09-12T00:57:58+10:00","created_at":"2021-09-12T00:57:58+10:00","vendor":"Hilitand","type":"Current Monitoring Relays","tags":["cocoon"],"price":14700,"price_min":14700,"price_max":14700,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":41111082270875,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"B07N1P6TWL","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Current Sensing Switch, Normally Open Current Sensing Relay Adjustable AC 0.2A -30A (SZC23-NO-AL-CH Model)","public_title":null,"options":["Default Title"],"price":14700,"weight":59,"compare_at_price":null,"inventory_management":null,"barcode":"Hilitand8k3b14u2na","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/leoforward.com\/cdn\/shop\/products\/B07N1P6TWL.jpg?v=1651434418","\/\/leoforward.com\/cdn\/shop\/products\/514g5zlgpdL.jpg?v=1631430991","\/\/leoforward.com\/cdn\/shop\/products\/6130RU8rJVL.jpg?v=1631430991","\/\/leoforward.com\/cdn\/shop\/products\/7119fKkQSDL_795bb5dd-15bf-4a5c-bc6e-e7bbe1843f83.jpg?v=1631430991","\/\/leoforward.com\/cdn\/shop\/products\/61SB6SYB0YL_5c302dfd-5bc4-4a25-ae01-e5fa10bc5b9a.jpg?v=1631430991","\/\/leoforward.com\/cdn\/shop\/products\/61Ai3Ck1CtL_0015afa3-5949-49e0-b9f6-e4777b1c70cb.jpg?v=1631430991","\/\/leoforward.com\/cdn\/shop\/products\/51Mz_6GOMnL_911b83af-97f8-4835-b12f-3672796a789c.jpg?v=1631430991","\/\/leoforward.com\/cdn\/shop\/products\/51PIkAGpaTL_22d7645b-1ff2-4090-877d-5274a357912c.jpg?v=1631430991","\/\/leoforward.com\/cdn\/shop\/products\/613sCq2v41L.jpg?v=1631430991"],"featured_image":"\/\/leoforward.com\/cdn\/shop\/products\/B07N1P6TWL.jpg?v=1651434418","options":["Title"],"media":[{"alt":"Current Sensing Switch, Normally Open Current Sensing Relay Adjustable AC 0.2A -30A (SZC23-NO-AL-CH Model) - LeoForward Australia","id":29662473257197,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1001,"width":1001,"src":"\/\/leoforward.com\/cdn\/shop\/products\/B07N1P6TWL.jpg?v=1651434418"},"aspect_ratio":1.0,"height":1001,"media_type":"image","src":"\/\/leoforward.com\/cdn\/shop\/products\/B07N1P6TWL.jpg?v=1651434418","width":1001},{"alt":"Current Sensing Switch, Normally Open Current Sensing Relay Adjustable AC 0.2A -30A (SZC23-NO-AL-CH Model) - LeoForward Australia","id":24844479529115,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1001,"width":1001,"src":"\/\/leoforward.com\/cdn\/shop\/products\/514g5zlgpdL.jpg?v=1631430991"},"aspect_ratio":1.0,"height":1001,"media_type":"image","src":"\/\/leoforward.com\/cdn\/shop\/products\/514g5zlgpdL.jpg?v=1631430991","width":1001},{"alt":"Current Sensing Switch, Normally Open Current Sensing Relay Adjustable AC 0.2A -30A (SZC23-NO-AL-CH Model) - LeoForward Australia","id":24844479561883,"position":3,"preview_image":{"aspect_ratio":1.0,"height":1001,"width":1001,"src":"\/\/leoforward.com\/cdn\/shop\/products\/6130RU8rJVL.jpg?v=1631430991"},"aspect_ratio":1.0,"height":1001,"media_type":"image","src":"\/\/leoforward.com\/cdn\/shop\/products\/6130RU8rJVL.jpg?v=1631430991","width":1001},{"alt":"Current Sensing Switch, Normally Open Current Sensing Relay Adjustable AC 0.2A -30A (SZC23-NO-AL-CH Model) - LeoForward Australia","id":24844479594651,"position":4,"preview_image":{"aspect_ratio":1.0,"height":1001,"width":1001,"src":"\/\/leoforward.com\/cdn\/shop\/products\/7119fKkQSDL_795bb5dd-15bf-4a5c-bc6e-e7bbe1843f83.jpg?v=1631430991"},"aspect_ratio":1.0,"height":1001,"media_type":"image","src":"\/\/leoforward.com\/cdn\/shop\/products\/7119fKkQSDL_795bb5dd-15bf-4a5c-bc6e-e7bbe1843f83.jpg?v=1631430991","width":1001},{"alt":"Current Sensing Switch, Normally Open Current Sensing Relay Adjustable AC 0.2A -30A (SZC23-NO-AL-CH Model) - LeoForward Australia","id":24844479627419,"position":5,"preview_image":{"aspect_ratio":1.0,"height":1001,"width":1001,"src":"\/\/leoforward.com\/cdn\/shop\/products\/61SB6SYB0YL_5c302dfd-5bc4-4a25-ae01-e5fa10bc5b9a.jpg?v=1631430991"},"aspect_ratio":1.0,"height":1001,"media_type":"image","src":"\/\/leoforward.com\/cdn\/shop\/products\/61SB6SYB0YL_5c302dfd-5bc4-4a25-ae01-e5fa10bc5b9a.jpg?v=1631430991","width":1001},{"alt":"Current Sensing Switch, Normally Open Current Sensing Relay Adjustable AC 0.2A -30A (SZC23-NO-AL-CH Model) - LeoForward Australia","id":24844479660187,"position":6,"preview_image":{"aspect_ratio":1.0,"height":1001,"width":1001,"src":"\/\/leoforward.com\/cdn\/shop\/products\/61Ai3Ck1CtL_0015afa3-5949-49e0-b9f6-e4777b1c70cb.jpg?v=1631430991"},"aspect_ratio":1.0,"height":1001,"media_type":"image","src":"\/\/leoforward.com\/cdn\/shop\/products\/61Ai3Ck1CtL_0015afa3-5949-49e0-b9f6-e4777b1c70cb.jpg?v=1631430991","width":1001},{"alt":"Current Sensing Switch, Normally Open Current Sensing Relay Adjustable AC 0.2A -30A (SZC23-NO-AL-CH Model) - LeoForward Australia","id":24844479692955,"position":7,"preview_image":{"aspect_ratio":1.0,"height":1001,"width":1001,"src":"\/\/leoforward.com\/cdn\/shop\/products\/51Mz_6GOMnL_911b83af-97f8-4835-b12f-3672796a789c.jpg?v=1631430991"},"aspect_ratio":1.0,"height":1001,"media_type":"image","src":"\/\/leoforward.com\/cdn\/shop\/products\/51Mz_6GOMnL_911b83af-97f8-4835-b12f-3672796a789c.jpg?v=1631430991","width":1001},{"alt":"Current Sensing Switch, Normally Open Current Sensing Relay Adjustable AC 0.2A -30A (SZC23-NO-AL-CH Model) - LeoForward Australia","id":24844479725723,"position":8,"preview_image":{"aspect_ratio":1.0,"height":1001,"width":1001,"src":"\/\/leoforward.com\/cdn\/shop\/products\/51PIkAGpaTL_22d7645b-1ff2-4090-877d-5274a357912c.jpg?v=1631430991"},"aspect_ratio":1.0,"height":1001,"media_type":"image","src":"\/\/leoforward.com\/cdn\/shop\/products\/51PIkAGpaTL_22d7645b-1ff2-4090-877d-5274a357912c.jpg?v=1631430991","width":1001},{"alt":"Current Sensing Switch, Normally Open Current Sensing Relay Adjustable AC 0.2A -30A (SZC23-NO-AL-CH Model) - LeoForward Australia","id":24844479758491,"position":9,"preview_image":{"aspect_ratio":1.0,"height":1001,"width":1001,"src":"\/\/leoforward.com\/cdn\/shop\/products\/613sCq2v41L.jpg?v=1631430991"},"aspect_ratio":1.0,"height":1001,"media_type":"image","src":"\/\/leoforward.com\/cdn\/shop\/products\/613sCq2v41L.jpg?v=1631430991","width":1001}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eCurrent Sensing Switch, Normally Open Current Sensing Relay Adjustable AC 0.2A -30A (SZC23-NO-AL-CH Model)\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eFeatures: Self-powered, no external power supply required.\nAction current 0.2-30A AC, adjustable with a potentiometer. LED indicator can\nconveniently and intuitively indicate the working status of the switch. High-\npower MOS tube contactless electronic switch. No limit on the number of\nopening and closing, and the reaction speed reaches the ms level. Straight-\nthrough structure design, isolation withstand voltage up to 2000V. Hysteresis\nis less than 1% and can be used under strong magnetic conditions. The outer\ncasing is made of self-extinguishing material ABS. Specification: Model:\nSZC23-NO-AL-CHPower supply: Not requiredRated load: ≤ 0.5A@240V AC\/DCInput\ncurrent: 0.2-30A ACSwitch on minimum: 0.5±0.2AMaximum overload: 100%Leakage\ncurrent: ≤0.1AAccuracy: 1%Hysteresis: ≤1%Response time: ≤200ms Repeatability:\n100%Working temperature: -20~60℃Waterproof: IP30Dimensions: 652547mm \/\n2.560.981.85inHole diameter: 10mm \/ 0.4inPackage weight: Approx. 56g\/2.0oz\nPackage list: 1 Current Sensing Switch Read more SZC23-NO-AL-CH For example:\nSZC23-NO-AL-CH The meaning is: this device is a current induction switch, the\nmaximum load of the switch is 0.5A@240V AC\/DC; the default is normally open;\nthe switching action current is adjustable; the device is a round fixed port.\n1: Type: SZC is a current induction switch; 2: Model series: The maximum\ncapacity of 23 series switches is 0.5A@240V AC\/DC; 3: NO stands for normally\nopen, that is, when the through-core current is less than the set value, the\nswitch is opened, and when the current is greater than the set value, the\nswitch is closed; 4: Whether the operating current of the switch can be\nadjusted: AL: stands for adjustable, that is, the user can adjust the\noperating current of the switch by himself; 5: The shape of the fixed port of\nthe device: CH stands for the round fixed port, that is, the wire must pass\nthrough the hole. Working Principle: Based on electromagnetic induction, when\nthe current in the circuit changes, an induced current is generated.This\nseries of AC current induction switch uses the inductance coil to induce the\namplitude of the AC current to determine whether it exceeds the preset current\naction value to change the output state of a solid state switch, similar to\nthe function of a mechanical switch. Read more Precautions: Before making\nelectrical connections, disconnect all power supplies in the circuit to avoid\nelectric shock accidents.The meaning of different indicators: For NO normally\nopen type, the green light indicates that the switch is off, current flows\nthrough the switch, but the starting value is not reached, and the contact is\noff; The red light indicates that the switch is closed, the current reaches\nthe starting value, and the contact is closed, the switch is in working\ncondition. Read more SZC23 series AC current sensing switch is designed and\nmanufactured to solve the AC current monitoring. It uses the principle of\nmutual inductance to sense the AC straight-through current, isolate the AC\ncurrent, and output a normally open or normally closed switching signal to\ndirectly control various automation industrial equipment, such as flash,\nbuzzer, relay, single-chip or other power load equipment. Compared with\ntraditional mutual inductors, thermal protectors and other devices, using this\ndevice can not only get more accurate and more timely control, but can also\ngreatly simplify the design and reduce costs.Suitable for AC current\nmeasurement and monitoring, AC motor overload protection, electronic switch of\nautomatic control system and so on. Read more Instructions: Typical Wiring\nDiagram Directly control AC and DC loadsIndirectly control AC and DC loads in\ncombination with contactors Cooperate with PLC to control AC motor Read more\nInstallation Instructions: Disconnect all power supplies in the circuit, and\nfix the AC current sensor switch in a proper position through the mounting\nhole of the base. If you use screws to install, make sure to tighten each\nscrew.Connect the core current loop, first disconnect the tested circuit, let\nthe tested circuit pass through the induction hole of the current switch, and\nreconnect the circuit; Connect the load circuit, note that the maximum AC load\nof this series of current switches cannot exceed 0.5A@240V AC\/DC.After\nchecking that the installation connection is correct, turn on the power switch\nand set the upper and lower limits of the induction switch current according\nto the user's needs: NO normally open type If the red light is on at this\ntime, adjust the potentiometer to the H direction until the green light is on\nand stop, then adjust it to the L direction, and then stop when the red light\nis on. If the green light is on at this time, turn the adjustable\npotentiometer to the L direction until the red light just lights up and stop.\nThe alternating point of the red and green lights is the current value of the\ncurrent through the heart. Common Problems and Solutions: After the\npenetration current reaches the set value, the load circuit is not\nautomatically connected: Solution: Check whether the wiring of the output\nsignal is loose and whether the load circuit wiring is loose. If an AC\ncontactor is used, check whether the wiring of the AC contactor is loose and\nwhether the AC contactor is damaged.After the AC feedthrough current is\napplied, the two LED indicators are off: Solution: Check whether the input AC\ncurrent is normal and whether the wiring is loose.After the AC feedthrough\ncurrent is applied, both LED indicators are on: Solution: The input AC\nfeedthrough current is too large, pay attention to the feedthrough current not\ntoo large, if it exceeds the allowable range of the current sensor switch, the\nswitch will be damaged.\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eSelf-powered, no external power supply required.\u003c\/li\u003e\n \u003cli\u003eAction current 0.2-30A AC, adjustable with a potentiometer.\u003c\/li\u003e\n \u003cli\u003eLED indicator can conveniently and intuitively indicate the working status of the switch.\u003c\/li\u003e\n \u003cli\u003eHigh-power MOS tube contactless electronic switch.\u003c\/li\u003e\n \u003cli\u003eThe switch has no limit on the number of opening and closing, and the reaction speed reaches the ms level.\u003c\/li\u003e\n \u003c\/ul\u003e\n\n\n\n\n"}

Current Sensing Switch, Normally Open Current Sensing Relay Adjustable AC 0.2A -30A (SZC23-NO-AL-CH Model)

In Stock. Leaves warehouse within 2 - 3 business days

$147.00 AUD
Maximum quantity available reached.
Free Shipping Australia Wide
100% Safe & Secure Checkout
100 Days Return Policy *
1 Year Warranty *

Current Sensing Switch, Normally Open Current Sensing Relay Adjustable AC 0.2A -30A (SZC23-NO-AL-CH Model)

Features: Self-powered, no external power supply required. Action current 0.2-30A AC, adjustable with a potentiometer. LED indicator can conveniently and intuitively indicate the working status of the switch. High- power MOS tube contactless electronic switch. No limit on the number of opening and closing, and the reaction speed reaches the ms level. Straight- through structure design, isolation withstand voltage up to 2000V. Hysteresis is less than 1% and can be used under strong magnetic conditions. The outer casing is made of self-extinguishing material ABS. Specification: Model: SZC23-NO-AL-CHPower supply: Not requiredRated load: ≤ 0.5A@240V AC/DCInput current: 0.2-30A ACSwitch on minimum: 0.5±0.2AMaximum overload: 100%Leakage current: ≤0.1AAccuracy: 1%Hysteresis: ≤1%Response time: ≤200ms Repeatability: 100%Working temperature: -20~60℃Waterproof: IP30Dimensions: 652547mm / 2.560.981.85inHole diameter: 10mm / 0.4inPackage weight: Approx. 56g/2.0oz Package list: 1 Current Sensing Switch Read more SZC23-NO-AL-CH For example: SZC23-NO-AL-CH The meaning is: this device is a current induction switch, the maximum load of the switch is 0.5A@240V AC/DC; the default is normally open; the switching action current is adjustable; the device is a round fixed port. 1: Type: SZC is a current induction switch; 2: Model series: The maximum capacity of 23 series switches is 0.5A@240V AC/DC; 3: NO stands for normally open, that is, when the through-core current is less than the set value, the switch is opened, and when the current is greater than the set value, the switch is closed; 4: Whether the operating current of the switch can be adjusted: AL: stands for adjustable, that is, the user can adjust the operating current of the switch by himself; 5: The shape of the fixed port of the device: CH stands for the round fixed port, that is, the wire must pass through the hole. Working Principle: Based on electromagnetic induction, when the current in the circuit changes, an induced current is generated.This series of AC current induction switch uses the inductance coil to induce the amplitude of the AC current to determine whether it exceeds the preset current action value to change the output state of a solid state switch, similar to the function of a mechanical switch. Read more Precautions: Before making electrical connections, disconnect all power supplies in the circuit to avoid electric shock accidents.The meaning of different indicators: For NO normally open type, the green light indicates that the switch is off, current flows through the switch, but the starting value is not reached, and the contact is off; The red light indicates that the switch is closed, the current reaches the starting value, and the contact is closed, the switch is in working condition. Read more SZC23 series AC current sensing switch is designed and manufactured to solve the AC current monitoring. It uses the principle of mutual inductance to sense the AC straight-through current, isolate the AC current, and output a normally open or normally closed switching signal to directly control various automation industrial equipment, such as flash, buzzer, relay, single-chip or other power load equipment. Compared with traditional mutual inductors, thermal protectors and other devices, using this device can not only get more accurate and more timely control, but can also greatly simplify the design and reduce costs.Suitable for AC current measurement and monitoring, AC motor overload protection, electronic switch of automatic control system and so on. Read more Instructions: Typical Wiring Diagram Directly control AC and DC loadsIndirectly control AC and DC loads in combination with contactors Cooperate with PLC to control AC motor Read more Installation Instructions: Disconnect all power supplies in the circuit, and fix the AC current sensor switch in a proper position through the mounting hole of the base. If you use screws to install, make sure to tighten each screw.Connect the core current loop, first disconnect the tested circuit, let the tested circuit pass through the induction hole of the current switch, and reconnect the circuit; Connect the load circuit, note that the maximum AC load of this series of current switches cannot exceed 0.5A@240V AC/DC.After checking that the installation connection is correct, turn on the power switch and set the upper and lower limits of the induction switch current according to the user's needs: NO normally open type If the red light is on at this time, adjust the potentiometer to the H direction until the green light is on and stop, then adjust it to the L direction, and then stop when the red light is on. If the green light is on at this time, turn the adjustable potentiometer to the L direction until the red light just lights up and stop. The alternating point of the red and green lights is the current value of the current through the heart. Common Problems and Solutions: After the penetration current reaches the set value, the load circuit is not automatically connected: Solution: Check whether the wiring of the output signal is loose and whether the load circuit wiring is loose. If an AC contactor is used, check whether the wiring of the AC contactor is loose and whether the AC contactor is damaged.After the AC feedthrough current is applied, the two LED indicators are off: Solution: Check whether the input AC current is normal and whether the wiring is loose.After the AC feedthrough current is applied, both LED indicators are on: Solution: The input AC feedthrough current is too large, pay attention to the feedthrough current not too large, if it exceeds the allowable range of the current sensor switch, the switch will be damaged.

Product Features

  • Self-powered, no external power supply required.
  • Action current 0.2-30A AC, adjustable with a potentiometer.
  • LED indicator can conveniently and intuitively indicate the working status of the switch.
  • High-power MOS tube contactless electronic switch.
  • The switch has no limit on the number of opening and closing, and the reaction speed reaches the ms level.